Fire-resistant duration of 3.5 hours: the standard weight of wall is 27.5 kg/square meter;
Fire-resistant duration of 5 hours: the standard weight of wall is 43.5 kg/square meter
No. |
Wall Structure |
Fire-resistant duration |
Explanation of Test Specimen |
|
1 |

|
3.5 hours* |
1. The face plate uses 10mm Strong-Enviro Board.
2. The framework uses UC75 standard light steel stud;
3. The insulation wool uses 50K×75mm thick rock wool. |
|
2 |

|
5 hours* |
1. The face plate uses of 10mm Strong-Enviro Board.
2. The framework uses UC75 standard light steel stud;
3. The insulation wool uses 50K×75mm thick rock wool. |
* As tested in Taiwan & China
Steel Structure Fire Protection
Characteristics:
Simple construction;
The shortest construction period;
Wall surface can be finished or left unfinished;
The optimal durability.
Steel Column Fire Protection System
Fire-resistant Performance of Strong-Enviro Board Protection Column
STRONG-ENVIRO BOARD, when used as a steel column fire protection system - surface finishes or connection to other walls does not affect its fire resistance.
STRONG-ENVIRO BOARD does not require maintenance to retain its fire resistance characteristics. Most other steel column fire protection systems are derived from surface applied chemicals which require continued maintenance.
Fire-resistant Performance
No. |
Steel Column Structure |
Fire-resistant Duration |
Explanation of Test Specimen |
01 |

|
2 hours* |
1. The face plate uses 18mm Strong-Enviro Board multifunctional boards.
2. The insulation wool uses 100K×20mm thick rock wool. |
02 |

|
3 hours* |
1. The face plate uses 18mm Strong-Enviro Board multifunctional boards.
2. The insulation wool uses 100K×20mm thick rock wool. |
*As tested in Taiwan & China